Error Code EEA
High

Amana AMVC960803BN Error Code EEA: Reversed Line Polarity

TL;DR
The furnace detected that the 115VAC supply wiring has reversed polarity — the hot and neutral wires are swapped. An electrician or HVAC technician must correct the wiring before the furnace can operate safely.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code EEA Mean?

Error code EEA on the Amana AMVC960803BN indicates that the integrated control module has detected reversed line polarity on the 115VAC power supply. The furnace will not operate because correct polarity is required for the control module to function safely and for the flame sense circuit to work properly.

The flame sense system in this furnace relies on the flame rectification principle — it measures the tiny DC microamp current that a flame allows to flow between the flame sensor rod and the grounded burner. This measurement only works correctly when line and neutral are wired to their correct terminals. Reversed polarity disrupts this circuit and can cause nuisance flame sensing problems in addition to the EEA fault.

The most common cause is incorrect wiring at the furnace disconnect switch, the circuit breaker panel, or an outlet, where the hot (black) and neutral (white) wires were swapped. Poor or missing unit ground can also trigger polarity-related faults. An electrician must verify wiring polarity with a voltmeter at the furnace power connection and trace the error to its source.

Common Causes

Cause Likelihood DIY?
115V AC power wired with reversed polarity (hot/neutral swapped) Most common ✗ Call a pro →
24V AC wires to transformer reversed Common ✗ Call a pro →
Poor unit ground connection Common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Sources

  1. Service Instructions - 34.5" Chassis ACVC96*BA/AMVC96*BA/GCVC96*BA/GMVC96*BA Gas Furnaces
  2. Amana AMVC960803BN Product Page

✓ Verified against manufacturer service manual — March 2026