This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code EE7 Mean?

Error code EE7 on the Amana AMVC960803BN indicates that the integrated control module has detected a fault in the igniter circuit. The furnace cannot proceed with an ignition sequence and will not operate until the condition is resolved.

The igniter circuit fault can have several origins. A shorted hot surface igniter — one whose resistance has dropped abnormally or whose element has cracked and is contacting a grounded surface — will cause the control to report EE7. An improperly connected igniter harness, such as reversed polarity or a plug that is not fully seated, can produce the same result. A poor or missing unit ground is another cause: without a proper ground, the control module cannot accurately sense the igniter circuit conditions and may report a fault. Finally, the igniter relay on the control board itself may have failed.

A technician will measure the igniter's resistance with a multimeter, inspect the wiring harness for damage or misconnections, verify the unit is properly grounded, and test the igniter relay on the control board to isolate the fault.

Common Causes

Cause Likelihood DIY?
Improperly connected or shorted igniter Most common ✗ Call a pro →
Poor unit ground Common ✗ Call a pro →
Igniter relay fault on control board Common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Sources

  1. Service Instructions - 34.5" Chassis ACVC96*BA/AMVC96*BA/GCVC96*BA/GMVC96*BA Gas Furnaces
  2. Amana AMVC960803BN Product Page

✓ Verified against manufacturer service manual — March 2026