Error Code Continuous OFF
High

Bryant 315AAV Error Code Continuous OFF: No Power

TL;DR
Your Bryant 315AAV has no power. The LED on the control board is completely off. Check if the circuit breaker has tripped or if the furnace power switch has been turned off.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code Continuous OFF Mean?

When the LED on your Bryant 315AAV control board is continuously off, it means the board is not receiving any electrical power. The furnace cannot operate at all in this state because the control board manages every function, from ignition to blower motor operation.

The most common cause is a tripped circuit breaker or blown fuse at your electrical panel. The second most likely cause is the furnace power switch being turned off. This switch is typically a standard light switch located on or near the furnace and can easily be bumped to the off position accidentally.

If both the breaker and power switch check out fine, the problem may be a faulty transformer or wiring issue inside the furnace. The manufacturer's manual specifies checking for 115 VAC at L1 and L2, and 24 VAC at SEC-1 and SEC-2, but these voltage measurements require specialized equipment and should be left to a qualified technician.

Common Causes

Cause Likelihood DIY?
Tripped circuit breaker or blown fuse Most common ✓ DIY fix →
Furnace power switch turned off Common ✓ DIY fix →
Faulty transformer or wiring Uncommon ✗ Call a pro →

How to Fix It: Check the Circuit Breaker and Power Switch

⚠ Safety First
Always turn off the furnace at the power switch or breaker and shut off the gas supply before beginning. Do not proceed if you smell gas — leave the area and call your gas company immediately.

What You'll Need

Steps

  1. Turn off the gas supply as a precaution Before investigating, turn the gas shutoff valve near the furnace to the OFF position (perpendicular to the pipe). Since the furnace has no power, there is no electrical switch to turn off, but securing the gas supply is an important safety step. If you smell gas at any point, leave immediately and call your gas company.
  2. Check the circuit breaker Go to your home's main electrical panel and find the breaker labeled for the furnace or HVAC system. If it is in the middle (tripped) position, flip it fully to OFF first, then back to ON. Some panels have fuses instead of breakers — check if the furnace fuse is blown and replace it with one of the same amperage.
  3. Check the furnace power switch Look for a standard light switch on or near the furnace, usually on the side of the unit or on a nearby wall. Make sure it is in the ON position. This switch is easily mistaken for a regular room light switch and may have been turned off accidentally.
  4. Restore gas and verify power Turn the gas supply valve back to ON (parallel to the pipe). Check the furnace control board through the sight glass on the blower access door — the LED should now be lit. Set your thermostat to call for heat and confirm the furnace starts its normal ignition sequence.
How to Verify
The amber LED on the control board should be continuously on (steady light), indicating the board has 24 VAC power and is in normal standby mode. When the thermostat calls for heat, the furnace should start its normal ignition sequence.

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Sources

  1. Bryant 315AAV/JAV Installation, Start-up, Operating and Service Instructions (II315A-70-13)

✓ Verified against manufacturer service manual — March 2026