Bryant 315AAV Furnace Error Codes

Single Stage Gas Furnace | Control Board: Variable Speed Furnace Control

Not your model? View all Bryant models →

Disclaimer
This information is for reference purposes only and does not guarantee accuracy or completeness. Always consult your owner's manual and a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

All Error Codes

Code Name Severity DIY?
Continuous OFF No Power High ✓ Yes
Continuous ON Normal Operation / Standby Info
Rapid Flashing Line Voltage Polarity Reversed High ✗ Call a pro
11 No Previous Code Info
12 Blower On After Power Up Info
13 Limit Circuit Lockout High ✓ Yes
14 Ignition Lockout High ✗ Call a pro
15 Blower Motor Lockout High ✗ Call a pro
21 Gas Heating Lockout High ✗ Call a pro
22 Abnormal Flame-Proving Signal High ✗ Call a pro
23 Pressure Switch Did Not Open High ✗ Call a pro
24 Secondary Voltage Fuse Is Open High ✗ Call a pro
25 Invalid Model Selection or Setup Error Low ✗ Call a pro
31 High-Heat Pressure Switch Open or Relay Did Not Close High ✗ Call a pro
32 Low-Heat Pressure Switch Open High ✗ Call a pro
33 Limit Circuit Fault High ✓ Yes
34 Ignition Proving Failure High ✗ Call a pro
41 Blower Motor Fault High ✗ Call a pro
43 Low-Heat Pressure Switch Open While High-Heat Pressure Switch Is Closed High ✗ Call a pro
45 Control Circuitry Lockout High ✗ Call a pro

How to Read the Error Code

The control in this furnace is equipped with a Status Code LED (Light-Emitting Diode) to aid in installation, servicing, and troubleshooting. Status codes can be viewed at the sight glass in blower access door. The amber furnace control LED is either ON continuously, rapid flashing, or a code composed of 2 digits. The first digit is the number of short flashes, the second digit is the number of long flashes.

About This Model

The Bryant 315AAV is a single stage gas furnace using the Variable Speed Furnace Control control board.