Error Code 4 Blinks (2-sec pause)
High

Ruud UGPH-07EAMGR Error Code 4 Blinks (2-sec pause): Pressure Switch Shorted

TL;DR
The pressure switch is stuck closed when it should be open, preventing the furnace from verifying safe exhaust venting.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code 4 Blinks (2-sec pause) Mean?

A 4-blink code on the Ruud UGPH-07EAMGR means the pressure switch contacts are remaining in the closed position when they should be open. The pressure switch is a safety device that monitors exhaust venting — it should only close when the inducer motor creates sufficient draft. When it stays closed at the wrong time, the control board cannot confirm that the venting system is working correctly.

The most common cause is a faulty pressure switch with stuck internal contacts. Over time, the diaphragm inside the switch can become stuck or the contacts can weld together, keeping the switch permanently closed. Less commonly, water or moisture accumulation in the pressure switch or its hoses can hold the contacts closed, and shorted wiring between the switch and the control board can mimic a stuck switch.

Do not attempt to bypass or jumper the pressure switch, as it is a critical safety device designed to prevent carbon monoxide exposure. A qualified HVAC technician needs to test the pressure switch, inspect the hose connections, and replace the switch if its contacts are stuck.

Common Causes

Cause Likelihood DIY?
Stuck pressure switch contacts Most common ✗ Call a pro →
Shorted wiring to pressure switch Uncommon ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Sources

  1. Ruud UGPH/UGPJ/UGDG/UGDJ/UGVH/UGVJ/UGLH/UGLJ Installation Instructions

✓ Verified against manufacturer service manual — March 2026