Payne PG96VTA Furnace Error Codes

Two Stage Gas Furnace | Control Board: Furnace Control CPU

Not your model? View all Payne models →

Disclaimer
This information is for reference purposes only and does not guarantee accuracy or completeness. Always consult your owner's manual and a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

All Error Codes

Code Name Severity DIY?
Continuous OFF No Power / Control Failure High ✓ Yes
Continuous ON Normal Operation - No Call for Heat Info
Rapid Flashing Reversed Polarity / Not Grounded High ✗ Call a pro
11 No Previous Code Info
12 Blower On After Power Up Info
13 Limit Circuit Lockout High ✓ Yes
14 Ignition Lockout High ✗ Call a pro
21 Gas Heating Lockout High ✗ Call a pro
22 Abnormal Flame-Proving Signal High ✗ Call a pro
23 Pressure Switch Did Not Open High ✗ Call a pro
24 Secondary Voltage Fuse Is Open High ✗ Call a pro
25 Invalid Model Selection or Setup Error Low ✗ Call a pro
31 High-Heat Pressure Switch or HPSR Relay Did Not Close or Reopened High ✗ Call a pro
32 Low-Heat Pressure Switch Did Not Close or Reopened High ✗ Call a pro
33 Limit Circuit Fault High ✓ Yes
34 Ignition Proving Failure High ✗ Call a pro
43 Low-Heat Pressure Switch Open While High-Heat Pressure Switch Is Closed High ✗ Call a pro
45 Control Circuitry Lockout High ✗ Call a pro

How to Read the Error Code

The control in this furnace is equipped with a Status Code LED (Light-Emitting Diode). The amber furnace control LED is either ON continuously, rapid flashing, or a code composed of 2 digits. The first digit is the number of short flashes, the second digit is the number of long flashes. Status codes can be viewed at the indicator in blower door.

About This Model

The Payne PG96VTA is a two stage gas furnace using the Furnace Control CPU control board.