All Error Codes

Code Name Severity DIY?
Continuous OFF No Power / Control Failure High ✓ Yes →
Continuous ON Normal Operation - No Call for Heat Info — →
Rapid Flashing Reversed Polarity / Not Grounded High ✗ Call a pro →
11 No Previous Code Info — →
12 Blower On After Power Up Info — →
13 Limit Circuit Lockout High ✓ Yes →
14 Ignition Lockout High ✗ Call a pro →
21 Gas Heating Lockout High ✗ Call a pro →
22 Abnormal Flame-Proving Signal High ✗ Call a pro →
23 Pressure Switch Did Not Open High ✗ Call a pro →
24 Secondary Voltage Fuse Is Open High ✗ Call a pro →
25 Invalid Model Selection or Setup Error Low ✗ Call a pro →
31 High-Heat Pressure Switch or HPSR Relay Did Not Close or Reopened High ✗ Call a pro →
32 Low-Heat Pressure Switch Did Not Close or Reopened High ✗ Call a pro →
33 Limit Circuit Fault High ✓ Yes →
34 Ignition Proving Failure High ✗ Call a pro →
43 Low-Heat Pressure Switch Open While High-Heat Pressure Switch Is Closed High ✗ Call a pro →
45 Control Circuitry Lockout High ✗ Call a pro →

How to Read the Error Code

The control in this furnace is equipped with a Status Code LED (Light-Emitting Diode). The amber furnace control LED is either ON continuously, rapid flashing, or a code composed of 2 digits. The first digit is the number of short flashes, the second digit is the number of long flashes. Status codes can be viewed at the indicator in blower door.

About This Model

The Payne PG96VTA is a two stage gas furnace using the Furnace Control CPU control board.