Trane TUD1B080A9H31B Furnace Error Codes

Single Stage Gas Furnace | Control Board: White-Rodgers 50A65 Integrated Furnace Control (IFC)

Not your model? View all Trane models →

Disclaimer
This information is for reference purposes only and does not guarantee accuracy or completeness. Always consult your owner's manual and a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

All Error Codes

Code Name Severity DIY?
Slow Flash Normal - No Call for Heat Info
Fast Flash Normal - Call for Heat Info
Continuous ON Replace IFC High ✗ Call a pro
Continuous OFF Check Power High ✓ Yes
2 Flashes System Lockout (Retries or Recycles Exceeded) High ✗ Call a pro
3 Flashes Draft Pressure Error High ✗ Call a pro
4 Flashes Open Temperature Limit Circuit High ✓ Yes
5 Flashes Flame Sensed When No Flame Should Be Present High ✗ Call a pro
6 Flashes 115V AC Power Reversed, Poor Grounding, or System Voltage Too Low Low ✗ Call a pro
7 Flashes Gas Valve Circuit Error High ✗ Call a pro
8 Flashes Low Flame Sense Signal Low ✗ Call a pro
9 Flashes Igniter Circuit / Grounding Fault High ✗ Call a pro

How to Read the Error Code

The Integrated Furnace Control (IFC) has an LED that communicates furnace status and error conditions through flash patterns. A slow flash indicates normal standby, a fast flash indicates a call for heat is active, and numbered flash sequences (2 through 9) indicate specific fault conditions.

About This Model

The Trane TUD1B080A9H31B is a single stage gas furnace using the White-Rodgers 50A65 Integrated Furnace Control (IFC) control board.