All Error Codes

Code Name Severity DIY?
Slow Flash Normal - No Call for Heat Info
Fast Flash Normal - Call for Heat Info
Continuous ON Replace IFC High ✗ Call a pro
Continuous OFF Check Power High ✓ Yes
2 Flashes External Lockout (Retries or Recycles Exceeded) High ✗ Call a pro
3 Flashes Pressure Switch Error High ✗ Call a pro
4 Flashes Open Limit Device High ✓ Yes
5 Flashes Flame Sensed When No Flame Should Be Present High ✗ Call a pro
6 Flashes 115V AC Power Reversed or Poor Grounding Low ✗ Call a pro
7 Flashes Gas Valve Circuit Error High ✗ Call a pro
8 Flashes Low Flame Sense Signal Low ✗ Call a pro
9 Flashes Check Igniter High ✗ Call a pro

How to Read the Error Code

The Integrated Furnace Control (IFC) has a diagnostic LED that communicates furnace status and error conditions through flash patterns. A slow flash indicates normal standby, a fast flash indicates an active call for heat, and numbered flash sequences (2 through 9) indicate specific fault conditions.

About This Model

The Trane TUH1B080A9H31A is a single stage gas furnace using the Integrated Furnace Control (IFC) control board.