Goodman GMEC960803BN Furnace Error Codes

Multi Speed Gas Furnace | Control Board: Integrated Control Module (Tri-Color LED)

Not your model? View all Goodman models →

Disclaimer
This information is for reference purposes only and does not guarantee accuracy or completeness. Always consult your owner's manual and a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

All Error Codes

Code Name Severity DIY?
No LED Signal No Power High ✓ Yes
Green LED Solid On Standby Info
Green LED Rapid Flash Normal Operation - Fan Call (G) Info
Green 1 Flash Normal Operation - Low Stage Cooling (Ylo + G) Info
Green 2 Flashes Normal Operation - High Stage Cooling (Y + G) Info
Amber 1 Flash Normal Operation - First Stage Heat (W1) Info
Amber 2 Flashes Normal Operation - Second Stage Heat (W2) Info
Amber 3 Flashes W2 Present With No W1 Low ✗ Call a pro
Amber 4 Flashes Y Present With No G Call, Y1 Present With No G Call Low ✗ Call a pro
Amber Rapid Flash Low Flame Sense Current Low ✗ Call a pro
Red 1 Flash Flame Sensed When No Flame Should Be Present High ✗ Call a pro
Red 2 Flashes Pressure Switch Stuck Closed / Inducer Error High ✗ Call a pro
Red 3 Flashes 1st-Stage Pressure Switch Stuck Open / Inducer Error High ✗ Call a pro
Red 4 Flashes Open Limit Switch High ✓ Yes
Red 5 Flashes Open Rollout / Open Fuse Detect High ✗ Call a pro
Red 6 Flashes Pressure Switch Cycle Lockout High ✗ Call a pro
Red 7 Flashes External Lockout (Retries) High ✗ Call a pro
Red 8 Flashes External Lockout (Recycles) High ✗ Call a pro
Red 9 Flashes Grounding or Reversed Polarity High ✗ Call a pro
Red 10 Flashes Gas Flow With No Call for Heat High ✗ Call a pro
Red 11 Flashes Limit Switch Open - Blower Failure High ✗ Call a pro
Red 12 Flashes Ignitor Relay Failure High ✗ Call a pro
Red LED Solid On Internal Fault / GV Error / Micro / Frequency Check High ✗ Call a pro
Red LED Rapid Flash Twinning Error High ✗ Call a pro
Red 3 Double Flashes 2nd-Stage Pressure Switch Stuck Open / Inducer Error High ✗ Call a pro

How to Read the Error Code

The integrated control module uses a tri-color LED (Green, Amber, Red) diagnostic system. The ignition control is equipped with a momentary push button switch that can display the last five faults detected. The control must be in Standby Mode (no thermostat inputs). To clear the fault code memory, push and hold the "LAST ERROR" button for more than 5 seconds and less than 10 seconds. Furnace lockout results when a furnace is unable to achieve ignition after three attempts during a single call for heat, characterized by a non-functioning furnace and a one flash diagnostic LED code.

About This Model

The Goodman GMEC960803BN is a multi speed gas furnace using the Integrated Control Module (Tri-Color LED) control board.