Bryant 340MAV Error Code 33: Limit Circuit Fault
What Does Code 33 Mean?
Status code 33 on the Bryant 340MAV indicates a limit circuit fault. A limit switch or flame rollout switch is currently open, meaning the furnace has detected overheating. The blower will run for 4 minutes or until the switch closes again, whichever is longer.
This is an active warning — the furnace is trying to cool itself down. If the switch stays open for longer than 3 minutes, the code will escalate to lockout code 13 and the furnace will shut down completely. If the switch closes within 3 minutes, code 33 will continue to flash until the blower shuts off. The flame rollout switch, if tripped, requires a manual reset by pressing its red button.
The most common cause is a dirty air filter that restricts airflow across the heat exchanger, causing it to overheat. Blocked or closed supply and return vents can also reduce airflow enough to trigger the limit. Since the 340MAV is a direct-vent condensing furnace, a restricted vent pipe, inadequate combustion air supply, or excessive wind can also cause the flame rollout switch to trip. Less common causes include a loose blower wheel or a defective blower motor.
Common Causes
How to Fix It: Replace the Air Filter and Restore Airflow
What You'll Need
- Replacement air filter (correct size for your system) 🛒 Find at FiltersFast · 🛒 Find at Amazon
- Flashlight
Steps
- Turn off electrical power at the breaker and shut off the gas supply valve Locate the furnace circuit breaker and flip it to OFF. Turn the gas shutoff valve to the OFF position (perpendicular to the pipe). If you smell gas, leave immediately and call your gas company.
- Check and replace the air filter Remove the air filter from the return air duct or furnace filter slot. If it is visibly dirty or clogged, replace it with a new filter of the correct size. Make sure the airflow direction arrow on the new filter points toward the furnace.
- Verify all supply and return vents are open Walk through every room and ensure all supply registers and return grilles are fully open and not blocked by furniture, curtains, or rugs. Even a few closed vents can significantly restrict airflow and cause overheating.
- Inspect the blower area With the power off, look at the blower wheel through the access panel opening. Check for excessive dust buildup on the blower blades, which can reduce airflow. Also verify the blower wheel is securely attached to the motor shaft and not wobbling.
- Restore power and gas, then test Turn the gas supply valve to ON and flip the circuit breaker to ON. Set your thermostat to call for heat and monitor the furnace through its heating cycle.
When to Call a Professional
Contact a licensed HVAC technician if:
- Code 33 returns after replacing the filter and opening all vents
- The flame rollout switch has tripped (a red button on the switch needs manual reset)
- The blower wheel is loose, damaged, or excessively dirty
- You hear unusual noises from the blower motor
- The code escalates to lockout code 13 repeatedly
✓ Verified against manufacturer service manual — March 2026