Bryant 340MAV Error Code 12: Blower On After Power Up
What Does Code 12 Mean?
Status code 12 on the Bryant 340MAV is displayed when the circulating blower runs for 90 seconds immediately after the furnace is powered on. This occurs under two specific conditions: the unit was powered up while a call for heat was already active (R-W/W1 thermostat contacts closed), or the R-W/W1 contacts opened during a blower on-delay period.
The 90-second blower run is a protective measure in the integrated furnace control. When power is restored during an active heating call, the control cannot immediately verify whether the heat exchanger is already hot from a previous cycle before the outage. Running the blower for 90 seconds clears residual heat and allows the board to perform startup checks from a known thermal state before attempting ignition.
This code clears on its own once the blower cycle completes and the furnace proceeds through its normal startup sequence. It does not indicate a fault.
- No professional service is needed for this status. If the furnace does not begin a normal heating sequence after the 90-second blower cycle completes, contact a technician.
✓ Verified against manufacturer service manual — March 2026