Error Code EC4
Low

Goodman GMVC960803BN Error Code EC4: Equipment Relay Module Missing

TL;DR
The furnace expects an external equipment relay module to be present but cannot detect it. A technician should check whether the module is properly installed and connected, or install the required module.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code EC4 Mean?

Error code EC4 on the Goodman GMVC960803BN indicates that the integrated control module has been configured to work with an external equipment relay module but cannot detect that module on the ComfortNet network. The equipment relay module is an accessory component that provides additional control relay outputs for connected HVAC equipment such as a heat pump, air conditioner, or other system components.

This code typically appears when the furnace was previously commissioned with an equipment relay module installed and that module is no longer present — for example, if it was removed during service, if it has failed and dropped off the network, or if there is a wiring problem preventing communication. It can also appear if the system was configured to expect this module but it was never installed.

A technician must determine whether the equipment relay module should be present based on the system configuration, verify its wiring, and either restore the connection to the existing module or install a replacement. If the module is intentionally absent and the system does not require it, the configuration may need to be updated to match the current installation.

Common Causes

Cause Likelihood DIY?
Equipment relay module not installed or disconnected Most common ✗ Call a pro →
Faulty equipment relay module Common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Sources

  1. Service Instructions - 34.5" Chassis ACVC96*BA/AMVC96*BA/GCVC96*BA/GMVC96*BA Gas Furnaces

✓ Verified against manufacturer service manual — March 2026