Error Code 23
Low

Bryant 355MAV Error Code 23: Pressure Switch Did Not Open

TL;DR
Your Bryant 355MAV detected that a pressure switch did not open when expected. The pressure tubing may be blocked or the switch may be stuck closed.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code 23 Mean?

Status code 23 on the Bryant 355MAV means a pressure switch failed to open when the control board expected it to. During normal operation, the pressure switch should open when the inducer motor stops, confirming that draft has ceased. If the switch remains closed, the control cannot verify that the venting system is functioning properly between heating cycles.

The most common cause is obstructed pressure tubing. The small rubber or silicone hose that connects the pressure switch to the inducer housing can become blocked by condensation, debris, or insect nests. When the tubing is blocked, the pressure switch cannot sense the actual draft pressure and may remain in its last position.

A pressure switch stuck in the closed position is the other likely cause. The switch contains a flexible diaphragm and mechanical contacts that can wear over time. If the contacts weld together or the diaphragm becomes stiff, the switch may not open when pressure drops. A technician can test the switch by disconnecting the hose and checking whether the contacts open, then inspect and clear the tubing.

Common Causes

Cause Likelihood DIY?
Obstructed pressure tubing Most common ✗ Call a pro →
Pressure switch stuck closed Common ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Sources

  1. Bryant 355MAV Series I Installation, Start-up, and Operating Instructions

✓ Verified against manufacturer service manual — March 2026