Error Code 2 Flashes
High

Amana AMSS960803BN Error Code 2 Flashes: Pressure Switch Stuck Closed

TL;DR
Your Amana AMSS960803BN's pressure switch is stuck closed before the inducer motor has started. A technician needs to test and replace the pressure switch.
Disclaimer
This article is for informational purposes only and does not guarantee the accuracy or completeness of the information provided. Always turn off power and gas supply before attempting any repairs. If you smell gas, leave immediately and call your gas company. Consult a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

What Does Code 2 Flashes Mean?

Code 2 (2 Flashes) on the Amana AMSS960803BN means the pressure switch circuit is reading as closed before the induced draft blower begins operating. The pressure switch is a safety device designed to verify that the inducer motor is creating proper airflow to vent combustion gases. If the switch shows closed before the inducer even starts, the control module treats this as an unsafe condition and halts the ignition sequence.

The most common cause is a pressure switch whose internal contacts have physically stuck together. These are mechanical devices that cycle open and closed many times during each heating season, and over time the contacts can wear, corrode, or weld together. When this happens, the switch can no longer accurately report whether the inducer motor is running.

Less commonly, a short circuit in the pressure switch wiring can send a false closed signal to the control board. In either scenario, a technician will need to disconnect and test the pressure switch with a multimeter, inspect the wiring for damage, and replace the faulty component to restore normal operation.

Common Causes

Cause Likelihood DIY?
Pressure switch contacts stuck closed Most common ✗ Call a pro →
Short in pressure switch wiring Uncommon ✗ Call a pro →

When to Call a Professional

Contact a licensed HVAC technician if:

🔧 Find an HVAC Pro Near You
Compare quotes from HVAC pros in your area. Free quotes, no obligation.
Get Free Quotes
We earn a referral fee when you connect with a service provider through this link.

Sources

  1. Service Instructions - GMSS9*/GCSS9*/AMSS9*/ACSS9* Single Stage Gas Furnaces and Accessories

✓ Verified against manufacturer service manual — March 2026