Rheem RGRA-07EMAES Error Code 5 Blinks: Twin Fault
What Does Code 5 Blinks Mean?
A 5-blink pattern on the Rheem RGRA-07EMAES's green STATUS LED indicates a twin fault. This code relates to the twinning feature, which allows two furnaces to operate together as a paired system to provide greater heating capacity.
If your furnace is set up as a twinned unit, this fault can occur when the TWIN setting on one or both IFC (Integrated Furnace Control) boards is not properly configured, when the twin wires between the two units' TWIN terminals are not connected, when the transformers of the two units are out of phase (which can also cause the flame LED to appear dim), or when the two IFC boards have different part numbers.
If your furnace is a single (non-twinned) unit, this code typically means the TWIN switch or setting on the control board is accidentally set to the ON position when it should be OFF. A technician needs to verify the twinning configuration matches the actual installation — either properly configuring a twinned setup or ensuring the TWIN setting is off for a single furnace.
Common Causes
When to Call a Professional
Contact a licensed HVAC technician if:
- The furnace shows a 5-blink code and you have a twinned furnace setup
- The furnace shows a 5-blink code and it is a single (non-twinned) unit
- The code appeared after recent service work or a control board replacement