Coleman DGAA056BDTA Furnace Error Codes

Single Stage Gas Furnace | Control Board: Integrated Furnace Control Board

Not your model? View all Coleman models →

Disclaimer
This information is for reference purposes only and does not guarantee accuracy or completeness. Always consult your owner's manual and a licensed HVAC technician for diagnosis and repair. Any actions taken based on this information are at your own risk.

All Error Codes

Code Name Severity DIY?
Normal Operation Normal Operation Info — →
Ignition Failure Ignition Failure Medium ✗ Call a pro →
Pressure Switch Stuck Closed Pressure Switch Stuck Closed Medium ✗ Call a pro →
Pressure Switch Failed to Close Pressure Switch Failed to Close Medium ✗ Call a pro →
Limit Switch Open Limit Switch Open Medium ✗ Call a pro →
Gas Flow With No Call for Heat Gas Flow With No Call for Heat Critical ✗ Call a pro →
Reverse Polarity Reverse Polarity Critical ✗ Call a pro →
Internal Control Failure Internal Control Failure Critical ✗ Call a pro →

How to Read the Error Code

Single GREEN LED located behind a clear view port in the blower compartment door. Flash codes 1 through 6: LED turns ON for 1 second and OFF for 1 second, repeated for the code number. All flash code sequences broken by a 2-second OFF period. This is a DIFFERENT system from York TM9V/TM9T — Coleman DGAA uses only a single green LED with flash counts, NOT multi-color LEDs. The control includes a 60-minute automatic watchdog reset from lockout for faults 1, 3, 4 and Steady On.

About This Model

The Coleman DGAA056BDTA is a single stage gas furnace using the Integrated Furnace Control Board-series integrated furnace control (IFC) board.